Post by NA7Q » Wed Apr 29, 2020 4:42 pm

I have tested and confirmed that TGs with 6 or 7 digits do not work when using the RXGroup filtering option. I have tested with the latest official and it appears to be present. 1 through 5 works perfectly.


Email I received from a user of my builds:

Hi Michael !

I cannot register on the website. there are problems with the "Cookie Policy". (viewtopic.php?t=425)
Therefore I write you a personal mail to the OpenGD77-Firmware.

I work with the GD77 in the BM network. I am using firmware 1.57.20
Set monitor: -> RXGroup
RX group cannot decode a 6-digit BM-TG (e.g. 232707)
RX group only works with 1-digit to 5-digit BM-TG
Can you correct that, please?

Thanks for your work!
73 Alfred OE7ABH

VK3KYY
Posts: 7478
Joined: Sat Nov 16, 2019 3:25 am
Location: Melbourne, Australia

Re: RXGroup Filter doesn't work with TGs of 6 or 7 digits

Post by VK3KYY » Mon Jun 01, 2020 4:13 am

This was fixed a while ago